Hughes-Primeau Controls combines 135+ years of selling engineered heat tracing systems with over 50 years of experience from Thermon.
No other company in Ohio, Western Pennsylvania, or West Virginia
can match our heat tracing solutions, inventory, nor expertise.
A Drug Free Workplace |

|
The ThermTrac (skin-effect tracing) system is ideally suited for long transfer pipelines up to 12 miles (20 km) per circuit. The system is engineered for the specific application. In the SECT heating system, heat is generated on the inner surface of a ferromagnetic heat tube that is thermally coupled to the pipe to be heat traced. An electrically insulated, temperature-resistant conductor is installed inside the heat tube and connected to the tube at the far end. The tube and conductor are connected to an AC voltage source in a series connection. This method of heating is called skin-effect heating because the return path of the circuit current is pulled to the inner surface (approximately 1 mm) of the heat tube by both the skin effect and the proximity effect between the heat tube and the conductor. Maximum Operating Temperature: 392°F
A Thermon skin-effect tracing system minimizes the number of power supply points required by offering the longest circuit lengths available to the industry.
|
![]() ![]() |
|
Long Line Temperature Maintenance or Freeze Protection TEK series reistance constant watt heating cables are used where circuit lengths exceed
the limitations of parallel resistance heating cables
Operating Voltage: up to 575 VAC Maximum Operating Temperature: 215°F
|
![]() |
|
High performance HTEK series resistance constant watt heating cables are used where circuit lengths exceed the limitations of parallel resistance heating cables and high maintain temperatures or high temperature exposure is required. Maximum Operating Temperature: 400°F
Operating Voltage: up to 575 VAC
|
![]() |
|
Thermon offers complete project execution of steam and re-circulating fluid tracing systems. Design, optimization, installation, and commissioning of the tracing system by a single source ensures that accountability for the system performance rests in one location. Working from project-specific material and performance specifications, Thermon offers a complete system from header design through condensate collection.
|
![]() |